Responsible for ensuring that all electrical, mechanical, and fire/life safety equipment within the data center is operating at peak efficiency. This involves both planned preventative maintenance of equipment, daily corrective work, and emergency response to emergent issues. The technician serves as an expert technical resource reporting to a program manager, interacting with Onsite Engineering Operations (OEO) and any third party vendors. They are expected to be a singular focal point for all facility operations within a given data center and to support operated data centers. Data center equipment that supports mission-critical servers must maintain better than 99.999% uptime.
Experience:
Understand the function, purpose, nominal operating parameters, and how to operate/isolate and start up: MV/LV Distribution Boards, MV/LV Breakers, UPS, Generator, Batteries, STS, ATS, AHU, DX units, Chillers, Evap Washer Systems, CRAC Units, Fuel Systems, ASCO Systems, BMS System, EPMS System, and Fire Alarm System.
Conversant of the BMS and EPMS systems and the impact of any state change, capable of navigating the system, interpreting alarms, and able to perform controlled shutdowns/startups/equipment rotations.
Utilizes safe working practices; can apply lockout/tagout, SDS, applies good housekeeping methods, etc.
Ability to read and interpret wiring diagrams, blueprints, floor plans, construction documents, mechanical riser drawings, OEM operating and maintenance instructions, job specifications, and MOP/SOP's.
Understands the refrigeration cycles to include: identifying components in advanced refrigeration circuits, understanding how each component works, diagnosing and correcting problems in the refrigeration circuit, using manifold gauge set, pressure/temperature chart and temperature measuring devices for routine maintenance and to troubleshoot.
Ability to use hand tools and test equipment to install, troubleshoot, and repair new or replacement parts for existing units covered under CET1 classified procedures, according to specifications and established safety guidelines, relying on MOPs, manufactuer's literature, and industry best practices to perform tasks under supervision, and ensures activites are logged in CMMS.
Daily walk-through of facility documenting parameters such as power availability, temperature and humidity, alarm status, etc. to be catalogued and compared for identification of discrepancies and trends.
Ability to understand site-specific processes and procedures such as how to report an incident or outage, procedure execution, PM standards, CMMS system, as well as the use of Sharepoint to access CE procedures and training content.
Ability to learn how to access the site primary and secondary EOP's, and understand the purpose of each of the EOP's and the critical nature of being an operator and first responder in the datacenter.
Navigate and verify the nominal status of the electrical and mechanical infrastructure via the BMS and EPMS systems, following site MOP & SOP procedures.